Advanced Search
LI Yajuan, LI Wushen, XIE Qi. Research and prediction on cold cracking susceptibility of Nb-Mo X80 pipeline steel[J]. TRANSACTIONS OF THE CHINA WELDING INSTITUTION, 2010, (5): 105-108.
Citation: LI Yajuan, LI Wushen, XIE Qi. Research and prediction on cold cracking susceptibility of Nb-Mo X80 pipeline steel[J]. TRANSACTIONS OF THE CHINA WELDING INSTITUTION, 2010, (5): 105-108.

Research and prediction on cold cracking susceptibility of Nb-Mo X80 pipeline steel

More Information
  • Received Date: June 27, 2009
  • The critical stresses of welding cold crack for Nb-Mo X80 pipeline steel was obtained by implant tests,it was found that its cold cracking susceptibility was low.The thermal cycle parameters,maximum hardness in HAZ and the original diffusible hydrogen content in deposited metal and diffusible hy-drogen content in deposited metal at 50℃ in different welding processes were measured,and the diffusible hydrogen content in deposited metal at 50℃ was calculated.The cold crack criterion equations of Nb-Mo X80 pipeline steel were established and ana-lyzed.The results show that the cold crack resistance of Nb-Mo X80 pipeline steel increases with the increase of maximum hard-ness in HAZ at the low diffusible hydrogen content,while it de-creases with the increase of maximum hardness in HAZ at the high diffusible hydrogen content.The cold crack sensitivity in-creases with the increase of the diffusible hydrogen content in the test maximum hardness scope.
  • Related Articles

    [1]ZHANG Qunbing, NIU Jing, ZHAO Pengfei, HUANG Yong, LI Zhigang, ZHANG Jianxun. Influence of preheating temperature on cold cracking sensitivity of 12Cr10Co3W2Mo heat resistant steel[J]. TRANSACTIONS OF THE CHINA WELDING INSTITUTION, 2015, 36(4): 87-91.
    [2]LI Yajuan, JIA Peng, LI Wushen, XIE Qi. Establishment of cold cracking susceptibility criterion for X80 pipeline steel[J]. TRANSACTIONS OF THE CHINA WELDING INSTITUTION, 2012, (4): 85-88.
    [3]HUANG Fuxiang, DU Zeyu, SUI Yongli, ZENG Huilin, GUO Xiaojiang. Study on cold cracking susceptibility of domestic X80 pipeline steel using implant tests[J]. TRANSACTIONS OF THE CHINA WELDING INSTITUTION, 2009, (4): 89-92.
    [4]DU Yi, ZHANG Tian-hong, ZHANG Jun-xu. Analysis on welding cold crack sensibility of 10Ni8CrMoV steel[J]. TRANSACTIONS OF THE CHINA WELDING INSTITUTION, 2006, (12): 93-96.
    [5]DU Ze-yu, TAO Yong-yin, LI Yun-tao, LI Jian-jun. Sulfide stress corrosion cracking and weldability of domestic X70 pipeline steels[J]. TRANSACTIONS OF THE CHINA WELDING INSTITUTION, 2004, (5): 13-16,21.
    [6]WANG Xue, SHI Yu-xiang, REN Yao-yao, LAI Jing-ping. Study of cold cracking susceptibility of CO2 gas shielded arc welded SA106C cast steel using implant tests[J]. TRANSACTIONS OF THE CHINA WELDING INSTITUTION, 2004, (4): 77-80.
    [7]ZHANG Xian-hui, CHEN Pei-yin, TAN Chang-ying. Effect of Stress and Plastic Strain on Hydrogen Diffusion In Welded Joint of Implant Test[J]. TRANSACTIONS OF THE CHINA WELDING INSTITUTION, 2002, (2): 9-12.
    [8]Li Zhiyuan, Hu Lunji, Lin Zhaofeng. STRESS RELAXATION TEST WITH SINGLE IMPLANT FOR REHEAT CRACKING TENDENCY ASSESSMENT OF LOW ALLOY STEELS[J]. TRANSACTIONS OF THE CHINA WELDING INSTITUTION, 1987, (1): 23-30.
    [9]Liang Dongtu, Wang Yingshu, Sun Yongling, Zhao Yuhua. RESEARCH ON STRESS RELIEF CRACKING OF LOW-ALLOY HIGH STRENGTH STEEL FOR PRESSURE VESSELS——Influence of Trace Boron on the Susceptibility of Mn-Mo-Nb Steel to SR Cracking[J]. TRANSACTIONS OF THE CHINA WELDING INSTITUTION, 1983, (1): 7-14.
    [10]Luo Zhichang, Zhang Lin, Li Naixuan, Wen Renqi. A STUDY ON HYDROGEN INDUCED DELAYED CRACKING WITH IMPLANT TEST IN Z-DIRECTION[J]. TRANSACTIONS OF THE CHINA WELDING INSTITUTION, 1982, (3): 125-138.

Catalog

    Article views (241) PDF downloads (82) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return