Fitting analysis on welding temperature field of fully welded valve
-
Graphical Abstract
-
Abstract
Welding temperature field was analyzed by using non-linear curve fit method based on experiments.The fitting temperature-time equation was obtained from actual data with an improved mathematic model.From different fitting equations under different conditions,regression coefficients were also analyzed.Considering the actual need,the location range of the sealing loop was acquired.
-
-